EG-COOL ROI Calculator

Scope restriction — locked per Eric, splits only until Michael confirms VRF. EG-COOL applies only to split units. The 27% figure was verified on exactly one inverter split unit — the verification's scope is the tool's scope, so centralized/VRF systems are paused (not excluded permanently) pending confirmation and a verified basis at the upcoming meeting. It does not apply to boilers, chillers, or compressors serving cold rooms / cold storage — that exclusion is permanent. If Michael confirms centralized/VRF applicability with a basis, this scope re-opens in one edit.

Prospect / Building

Tariff & Operating Settings

Baseline Cooling Load — Choose a Method

Itemizing is the more defensible number for a proposal. The bill-based estimate is a fast first pass for early-stage prospecting — use it to gauge whether a site is worth a full walkthrough, not as the number you'd put in a client-facing report.

Eligible Cooling Equipment (Split Units Only — VRF/Centralized Pending)

Add every split-unit or standalone package AC unit at this site. Quick-add presets below are pre-filtered to eligible equipment only — greyed-out items are shown for reference and cannot be added: boiler/chiller/cold-room items are permanently out of scope, and VRF/centralized items are paused pending Michael's confirmation.

Two ways to size a unit: enter its nameplate Watts directly, or switch a row to HP mode to match ESLIA's own ROI sheet — HP × kWh factor × hours, same formula ESLIA uses internally. The kWh factor below (0.75 kW drawn per HP) is ESLIA's own constant across every tier in their sheet.
UnitTypeInputWatts / HPQtyHrs/daykWh/dayUnit price (RM)

Baseline Cooling Load — Result

EG-COOL Savings & Payback

Only permissible savings figure — do not exceed. This tool caps assumed savings at 27%, the sole Technicity-verified figure: SIRIM Berhad ETRC Report ref R374/22 (J177/22, August 2022), ISO 14034:2016 ETV methodology, tested on a single inverter split unit at ESLIA's own premises. ESLIA's own internal ROI sheet uses 20–25% by HP tier — both under this cap, so the two are consistent. Do not quote a price or payback period to any client until ESLIA confirms unit pricing and MyHIJAU status in writing — the figures below are internal modelling only.
27%
The 27% figure was tested on a single inverter split unit — not a clinic ward, cold room, or manufacturing floor. Treat it as an upper-bound theoretical reference for sales conversation, not a guaranteed outcome for this specific site, until Technicity's own pilot instrumentation confirms higher-duty-cycle results.

12-Month Savings & Payback Schedule

Flat monthly projection at the assumed saving % above — no seasonality applied, since neither the SIRIM report nor ESLIA's sheet models month-to-month variation. Treat as an even-spread estimate, not a forecast of any specific month.

MonthkWh savedRM savedCumulative RM savedInvestment balance (RM)% investment recovered

Per-Unit Monthly Expectation (itemized equipment only)

Same 27%-capped saving % applied per unit type, so you can quote an individual unit's expected monthly saving rather than only the site total.

UnitQtykWh saved / month (per unit)RM saved / month (per unit)RM saved / month (all units of this type)